foofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofooairporthospitalsindustrylogisticsretailArtboardempowermentinnovationbrochureproductpassionproductsrespectteamworkArtboard@2xwhitepaperwiring-diagramsfacebookinstagramlinkedintwitteryoutubearrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

IS40 / XL

MOTION & PRESENCE SENSOR FAMILY FOR INDUSTRIAL DOORS
is40

Description

BEA’s IS40 / IS40XL are dual technology sensors designed to provide motion and presence detection in industrial applications. The standard IS40 can be mounted from 96 to 192 inches (8 ft × 16 ft) to fit any industrial application. For lower mounting heights, BEA’s IS40XL can be mounted from 78 to 138 inches (6.5 ft × 11.5 ft). Housed in a rugged NEMA 4 rated enclosure, the IS40 / IS40XL will operate in harsh environments, capable of withstanding damage caused by wind-blown dust and rain and hosedirected water.

Features

Energy savings

Bidirectional, unidirectional approach and unidirectional depart microwave detection options

Adjustable detection settings

Six modes of detection filtering are available for microwave immunity, as well as pedestrian and parallel traffic rejection

Customizable patterns

Nine unique infrared patterns capable of highly flexible presence detection in any industrial environment

Reduce false detections

Adjustable infrared immunity modes mitigate environmental disturbances such as subtle door vibrations, light, sun, rain and snow

Table of specifications

Technology

Microwave Doppler Radar

Active Infrared

Detection Mode

Motion

Presence

LED signal

Green (Activation Relay)

Red (Presence Relay)

Transmitter
Frequency / Wavelength

24.150 GHz

875 nm

Transmitter Power Density

< 5 mW / cm2

< 250 mW/m2

Max. Detection Field
IS40
IS40XL

 
156 in × 198 in
156 in × 78 in

 
120 in × 120 in
90 in × 90 in

Output Hold Time

0.5 s – 9 s

0.5 s

Min. Detection Speed

2 in / s in sensor axis

0 in / s

Tilt Angle

−8º – 22º
(Relative to sensor face)

15º – 45º

Mains Frequency

50 – 60 Hz

 

Power Consumption

< 3.5 W

 

Relay Output
Max. Contact Voltage
Max. Contact Current
Max. Switching Power

2 relays (free of potential change-over contact)
42 VAC / VDC
1 A (resistive)
30 W (DC) / 48 VA (AC)

 

Installation Height
IS40
IS40XL

 
96 in – 192 in (8 ft – 16 ft)
78 in – 138 in (6.5 – 11.5 ft)

 

Temperature Range

−22 ºF – 140 ºF

 

Dimensions

3.75 in (W) × 4 in (H) × 5 in (D)

 

Materials

ABS & Polycarbonate

 

Cable Length

360 in (30 ft)

 

Degree of Protection

NEMA 4 / IP65

 

Norm Conformance

R&TTE: 1999/5/EC;
EMC 2004/108/EEC

 
Versions
  • is40
    10IS40

    Dual technology motion and presence sensor for standard mounting heights

  • is40
    10IS40XL

    Dual technology motion and presence sensor for low mounting heights

Accessories
Videos
Downloads
Frequently asked questions

How do I set the IS40 so it detects vehicles but not people?

Set Detection filter (Rejection mode) to 3 or higher, walk-test, and then test with vehicle.

 

Why is the red LED on and the door is stuck open?

The Presence function of the sensor is in detection.

 

The sensor is set to not detect people.  Why is it still detecting people?

1. If the green LED illuminates, the microwave motion sensor is detecting people. Continue to troubleshoot the motion settings.

2. If the red LED illuminates, the active infrared presence sensor is detecting people. You need to adjust the AIR target size.

 

Why is the door recycling open?

The IS40 is detecting the motion of the door or sensing external vibrations.  You need to tilt the sensor out farther and/or reduce the detection field (Sensitivity).

 

How long is the cable?

33 feet

 

What is the power requirement for the IS40?

12 to 24 VAC ±10%; 12 to 24 VDC +30%/-10%

 

Why won’t the IS40 respond when I attempt to modify the Detection filter?

Verify that it is an IS40 and not an IS40P (presence detection only, no motion detection).

 

Why does the IS40 LED blink red quickly when I try to unlock it with the remote control?

A lock code has been entered. To remove it, cycle power on the IS40 and then press UNLOCK > LOCK > 0000 using the remote control.

 

Can the IS40 be used outdoors?

Yes, the IS40 has a NEMA 4 / IP65 rating. 

 

Can I adjust the IS40 without the remote control?

Yes, please reference the User’s Guide for manual adjustments.

 