foofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofooairporthospitalsindustrylogisticsretailArtboardempowermentinnovationbrochureproductpassionproductsrespectteamworkArtboard@2xwhitepaperwiring-diagramsfacebookinstagramlinkedintwitteryoutubearrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

IXIO-ST Industrial

SAFETY SENSOR FOR SMALL INTERIOR INDUSTRIAL DOORS
ixio-dt1_st

Description

BEA’s IXIO-ST Industrial is an effective, versatile and easy-to-use presence sensor for interior industrial doors, automatic sliding doors and off-door industrial automation. It can be used for both clear door openings and side-lite protection.

Precise infrared curtains coupled with visible alignment beams make the IXIO-ST Industrial extremely safe and easy to adjust. This state-of-the-art sensor features an on-board LCD screen that streamlines the installation and setup processes.

The IXIO-ST Industrial has earned a comprehensive list of credentials and certifications, including FCC and IP54.

Features

Precise presence detection

Two 24-spot, high-density infrared safety curtains providing precise presence detection

Quick set up

Four visible red alignment spots are projected on the ground to assist in precise IR curtain adjustment

Easy to program

Intelligent programming and troubleshooting via a menu-driven LCD

High performance

On-board microprocessor optimizes data analysis, monitors sensor performance and enables system integration

Table of specifications

Technology

Active Infrared

 

Detection Mode

Presence

 

Spot Size

2 in × 2 in

 

Max. Number of Spots

24 per curtain

 

Max. Number of Curtains

2

 

Output Relays
Max. Contact Current
Max. Contact Voltage
Hold Time

Electro-mechanical-relay (potential and polarity free)
1 A
30 VDC
Holdtime: 0.5 – 9 s

Solid-state-relay (potential and polarity free)
400 mA
42 VDC
Holdtime: 0.3 – 1 s

Test Input

N/A

Sensitivity: Low: < 1 V; High: > 10 V (max. 30 V)
Response time on test request: typical: < 5 ms

Supply Voltage

12 – 24 VAC ±10%; 12 – 30 VDC ±10% (to be operated from SELV compatible power supplies only)

 

Power Consumption

< 2.5 W

 

Mounting Height

78 in – 138 °F – 131 °F
0 – 95% relative humidity, non condensing

 

Temperature Range

−13 °F – 131 °F
0 – 95% relative humidity, non-condensing

 

Degree of Protection

IP54

 

Applicable Directives

R&TTE 1999 / 5 / EC; EMC 2004 / 108 / EC;
MD 2006 / 42 / EC; RoHS 2002 / 95 / EC

 

Dimensions

10.6 in (W) × 2.27 in (H) × 2.25 in (D)

 

Cable Length

360 in (30 ft)

 

Norm Conformance

EN 12978, EN ISO 13849-1:2008 PL <> CAT.2
(under the condition that the door control system monitors the sensor at least once per door cycle)
IEC 61496-1:2012 ESPE Type 2
EN 16005: 2012 Chapter 4.6.8;
DIN 18650-1:2010 Chapter 5.7.4
BS 7036-1:1996 Chapter 8.1

 
Versions
  • ixio-dt1_st
    10IXIOST INDUS

    Safety sensor for small interior industrial doors

Accessories
Downloads
Frequently asked questions

Why will the IXIO’s active infrared safety pattern not hold the door open?

The brown and blue wires must be connected, or F1 must be set to “1” using the remote control.

 

Why is the PNP harness not working on a BESAM control?

The harness is reversed; the short harness plugs into the IXIO.

 

Why is the RECORD sliding door holding open?

The RECORD control uses a normally closed safety circuit; set the safety output to N.C.

 

Why is the IXIO bliking red on a DORMA door?

The IXIO is defaulted to monitoring ON; connect the two (2) purple monitoring wires to the control.

 

How do I eliminate four (4) orange LED flashes or “low AIR”?

Verify the pattern width shutters are not closed (the software should still be set to wide).Verify the active infrared safety pattern is not tilted out too far away from the door.

Turn off the 2nd active infrared safety pattern row.

 

Why does the door recycle open?

If the red LED illuminates, the active infrared safety curtain needs adjusted.

If the green LED illuminates, the microwave activation angle/sensitivity/immunity needs adjusted.

 

What are the extra wires not connected to the door control?

The two (2) purple wires are for monitoring and the yellow wire is for N.C. activation relay.

 

How do I locate the IXIO’s active infrared safety pattern relative to the door face?

Double-click the gray knob to turn on the visible red aligment spots or press UNLOCK > MAGIC WAND > + on the remote control, and then use the red knob to adjust active infrared saftey pattern to within 3” of the face of the sliding door panel. After adjustment, relaunch a setup.

 

How do I use an IXIO for 1-way traffic reactivation?

If the door is equipped with a two-way traffic option, connect the white and green wires to the activation circuit.

If the door is NOT equipped with a two-way traffic option, DO NOT connect the white and green wires to the activation circuit; instead, connect the brown and blue wires to the safety circuit.

Using the LCD, set RAD: REENTRY to value “”3″” or “”4″”. Walk-test to ensure there is a minimum of a 24” reactivation zone.

 

Why does the IXIO LED blink fast red when I try to unlock it with the remote control?

A lock code has been entered. To remove it, power cycle the IXIO and then press UNLOCK > LOCK > 0000.

 