foofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofooairporthospitalsindustrylogisticsretailArtboardempowermentinnovationbrochureproductpassionproductsrespectteamworkArtboard@2xwhitepaperwiring-diagramsfacebookinstagramlinkedintwitteryoutubearrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

SuperScan-T

DOOR MOUNTED, ACTIVE INFRARED SAFETY SENSOR
superscan

Description

BEA’s SUPERSCAN-T is a door mounted, active infrared safety sensor designed for use on automatic swinging, revolving, folding and low energy doors.

The SUPERSCAN-T uses triangulation to detect the presence of a pedestrian, while the door is opening and closing.

The SUPERSCAN-T can be used as an individual module or daisy chained with additional slave modules. This flexibility allows the SUPERSCAN-T to be used on both narrow and wide doors. Each module detection zone can be adjusted independently.

Features

Customizable length

Housing available up to 102 inches in length; can be field cut to desired door width

Standards compliant

Capable of external monitoring

Functional Design

Designed to mount at the top of the door to reduce accidental damage

UL 10B/C Listed

Fire rated for up to 90 minutes

Table of specifications

Technology

Active Infrared with background suppression

 

Detection Mode

Presence

 

Measurement of Distance

Triangulation

 

Power Supply

12 to 24 VAC / VDC ±10%

 

Output Interface; Relay

Relay – max. contact rating: 1A @ 30 V (resistive)

 

Detection Range

0 – 8'

 

Distance Adjustment

2 – 8’ (rotating cam with linear adjustment)

 

Max. Mounting Height

8’

 

Detection Signal Duration

Infinite presence detection

 

Detection Time

< 50 ms

 

Output Hold Time

Potentiometer range: 0.1 – 4.5 seconds

 

Operating Temperature Range

–30 °F – 140 °F

 

PCB Dimensions
Master
Slave

 
10.91 in (W) × 1.5 in (H)
8.75 in (W) × 1.5 in (H)

 

Connector to Door Controller

8-position screw terminal on Master PCB

 

Master-to-Slave Connection

Flat-ribbon cable with connectors and key lock

 

Max. Number of Slaves

8

 

Functions Selection

Detection mode: NO or NC
Normal mode or Background Analysis mode

 

Norm Conformity

UL 10 B / C (90 minutes)1
UL 10 B file number: GVUX.R39071;
UL 10 C file number: GVUX7.R39071

 

1UL 10 fire rating applies only to SUPERSCAN-T sensors with housings less than or equal to
46 ½”. Housings greater than 46 ½” are not UL 10 fire-rated.

Versions
  • superscan
    10SSTI

    1 Master
    34.5 in (end cap to end cap)

  • superscan
    10SSTI40

    1 Master
    40 in (end cap to end cap)

  • superscan
    10SSTI42

    1 Master
    42 in (end cap to end cap)

  • superscan
    10SSTI48

    1 Master
    48 in (end cap to end cap)

  • superscan
    10SSTII

    1 Master 1 Slave
    34.5 in (end cap to end cap)

  • superscan
    10SSTII40

    1 Master 1 Slave
    40 in (end cap to end cap)

  • superscan
    10SSTII42

    1 Master 1 Slave
    42 in (end cap to end cap)

  • superscan
    10SSTII48

    1 Master 1 Slave
    48 in (end cap to end cap)

  • superscan
    10SSTIII

    1 Master 2 Slaves
    34.5 in (end cap to end cap)

  • superscan
    10SSTIIICUSTOM

    1 Master 2 Slaves
    Custom Length

  • superscan
    10SSTIVCUSTOM

    1 Master 3 Slaves
    Custom Length

  • superscan
    10SSTVCUSTOM

    1 Master 4 Slaves
    Custom Length

  • superscan
    10SSTVICUSTOM

    1 Master 5 Slaves
    Custom Length

  • superscan
    10SSTVIICUSTOM

    1 Master 6 Slaves
    Custom Length

  • superscan
    10SSTVIIICUSTOM

    1 Master 7 Slaves
    Custom Length

Accessories
  • q-disconnect
    SuperScan-T Q-Disconnect

    Quick Disconnect Harness for BEA’s SuperScan-T

Downloads
Frequently asked questions

What do the jumpers do? 

See “Mechanical Adjustments” section of the User’s Guide.

 

Why does the SUPERSCAN only detect when I’m standing on a ladder?

Ensure that the SUPERSCAN is mounted in the correct orientation (lens is facing down). 

 

Why does the door recycle open? 

The SUPERSCAN is detecting too far down.  Adjust the range by turning the potentiometer located in between the lenses; each click represents about 4″.

 

Which terminals power the SUPERSCAN?

Terminals 7 and 8

 

Why is the SUPERSCAN behaving as if it is wired normally closed but I have it wired normally open?

The SUPERSCAN changes relay state on power up.  For normally open operation, use terminals 5 and 6, and for normally closed operation, use terminals 4 and 6.

 

What adjustments can be made on the SUPERSCAN?

There are 3 basic mechanical adjustments:

1. Tilt angle is adjusted using the white clips in the housing.

2. Detection width is adjusted left or right by sliding the white clips in the housing.

3. Detection height is adjusted by turning the screw that moves the lenses closer together or farther apart.

 